P1281 Air Fuel Ratio Sensor 1 Circuit No Activity Detected Bank 2

P1281 Air Fuel Ratio Sensor 1 Circuit No Activity Detected Bank 2

Possible causes
– Faulty air fuel ratio (A/F) sensor 1 heater Bank 2
– Air fuel ratio (A/F) harness is open or shorted
– Air fuel ratio (A/F) circuit poor electrical connection
What about the obd code?
The A/F signal computed by ECM from the A/F sensor 1 signal is constantly approx. 0V.
Symptoms
– Engine Light ON (or Service Engine Soon Warning Light)
– Possible rough engine idle
P1281 Description

The A/F sensor is a planar dual-cell limit current sensor. The sensor element of the A/F sensor is the combination of a Nernst concentration cell (sensor cell) with an oxygen-pump cell, which transports ions. It has a heater in the element.

The sensor is capable of precise measurement