P1404 Mazda Exhaust Gas Recirculation Closed Position Performance

P1404 Mazda Exhaust Gas Recirculation Closed Position Performance

Possible causes
– Faulty Exhaust Gas Recirculation (EGR) valve
– Carbon blockage of the pintle
Tech description
On some models, there is a service bulletin for the P1404 Mazda code that suggest reprogramming the Powertrain Control Module (PCM) to repair the problem.
What about the obd code?
While monitoring the Exhaust Gas Recirculation (EGR) valve pintle position the Powertrain Control Module (PCM) detected the closed position sensor voltage higher than the learned closed position voltage.
Symptoms
– Engine Light ON (or Service Engine Soon Warning Light)
P1404 Mazda Description

The Powertrain Control Module (PCM) determines that the EGR valve is stuck open if the actual Exhaust Gas Recirculation (EGR) position and the learned closed EGR position vary by more than a predetermined value. The PCM tests for a stuck valve when the desired EGR position is at 0%. The PCM commands the EGR valve to 100% during certain driving conditions in order to clear a possible restriction from the EGR valve if the PCM determines that the valve is stuck open. The PCM retests for a stuck valve when the desired EGR position returns to 0%. A failure timer increments if the stuck EGR valve condition is still present. This DTC sets when the timer reaches a predetermined value.

Mazda Vehicle:Mazda B-Series, Mazda CX-7,Mazda CX-9,Mazda MAZDA2,Mazda MAZDA3,Mazda MAZDA5,Mazda MAZDA6,Mazda Miata MX-5,Mazda RX-8,Mazda Tribute,Mazda RX-8,Mazda MX-5,Mazda CX-9,Mazda Atenza,Mazda Axela,Mazda Tribute,