Mazda Factory OBD-II DTC P1245 Code Diagnostic Procedure

Mazda P1245 Generator load low input
DETECTION CONDITION
•  The PCM monitors the generator signal. If the voltage at PCM terminal 213 remains low, the PCM determines that there is a generator circuit problem.
POSSIBLE CAUSE
•  Generator malfunction
•  Short to ground circuit between generator connector terminal C and PCM terminal 213
•  Connector or terminal malfunction
•  PCM malfunction

Diagnostic procedure

STEP INSPECTION ACTION
1
VERIFY FREEZE FRAME DATA HAS BEEN RECORDED
•  Has the FREEZE FRAME DATA been recorded?
Yes
Go to the next step.
No
Record the FREEZE FRAME DATA on the repair order, then go to the next step.
2
VERIFY RELATED REPAIR INFORMATION AVAILABILITY
•  Verify related service repair information availability.
•  Is any related repair information available?
Yes
Perform repair or diagnosis according to the available repair information.
•  If the vehicle is not repaired, go to the next step.
No
Go to the next step.
3
VERIFY CURRENT SIGNAL STATUS: IS CONCERN INTERMITTENT OR CONSTANT?
•  Connect the M-MDS to the DLC-2.
•  Clear the DTC from the PCM memory using the M-MDS.
•  Run the vehicle under the FREEZE FRAME DATA stored condition.
•  Is the same DTC present?
Yes
Go to the next step.
No
Intermittent concern exists.
Perform the “INTERMITTENT CONCERNS TROUBLESHOOTING”.
4
INSPECT POOR CONNECTION OF GENERATOR CONNECTOR
•  Disconnect generator connector.
•  Inspect for poor connection (damaged, pulled-out terminals, corrosion, etc.).
•  Is there a malfunction?
Yes
Repair or replace terminals, then go to Step 8.
No
Go to the next step.
5
INSPECT GENERATOR
•  Inspect the generator.
•  Is there any malfunction?
Yes
Replace the generator, then go to Step 8.
No
Go to the next step.
6
INSPECT POOR CONNECTION OF PCM CONNECTOR
•  Turn the engine switch off.
•  Disconnect PCM connector.
•  Inspect for poor connection (damaged, pulled-out terminals, corrosion, etc.).
•  Is there any malfunction?
Yes
Repair terminals, then go to Step 8.
No
Go to the next step.
7
INSPECT GENERATOR CONTROL CIRCUIT FOR SHORT TO GROUND
•  Turn the engine switch off.
•  Inspect for continuity between generator terminal C (wiring harness-side) and body ground.
•  Is there continuity?
Yes
Repair or replace the wiring harness for short to ground, then go to the next step.
No
Go to the next step.
8
VERIFY THAT DTC P1245 TROUBLESHOOTING IS COMPLETED
•  Make sure to reconnect all connectors.
•  Clear DTC from PCM memory using M-MDS.
•  Run the vehicle under the FREEZE FRAME DATA stored condition.
•  Is the same DTC present?
Yes
Replace PCM, then go to the next step.
No
Go to the next step.
9
VERIFY AFTER REPAIR PROCEDURE
•  Perform the after repair procedure.
•  Are any DTCs present?
Yes
Go to the applicable DTC inspection.
No
DTC troubleshooting completed.